    [科技报告]   Cantrell, J. H.   Cantrell, S. A.        共22页
    摘要 : The increasing use of dynamic atomic force microscopy (d-AFM) for nanoscale materials characterization calls for a deeper understanding of the cantilever dynamics influencing scan stability, predictability, and image quality. Mode... 展开

    [科技报告]   Wang, N.   Lobkis, O. I.   Rokhlin, S. I.   Cantrell, J. H.        共8页
    摘要 : The inverse determination of imperfect interfaces from reflection spectra of normal and oblique incident ultrasonic waves in adhesive bonds of multidirectional composites is investigated. The oblique measurements are complicated b... 展开

    [科技报告]   Cantrell, J. H.        共7页
    摘要 : It is shown that the shapes of acoustic radiation-induced static strain and displacement pulses (rectified acoustic pulses) are defined locally by the energy density of the generating waveform. Dispersive properties are introduced... 展开

    [科技报告]   Cantrell, J. H.        共15页
    摘要 : Safe-life and damage-tolerant design philosophies of high performance structures have driven the development of various methods to evaluate nondestructively the accumulation of damage in such structures resulting from cyclic loadi... 展开

    [科技报告]   Pretlow, R. A.   Yost, W. T.   Cantrell, J. H.        共22页
    摘要 : A system for and method of detecting and measuring concentrations of anultrasonically-reflective microsphere contrast agent involving detecting non-linear sum and difference beat frequencies produced by the microspheres when two i... 展开

    [科技报告]   Yost, W. T.   Wait, J. L.   Nahormek, P. A.   Cantrell, J. H.   Hanna-hawver, P. D.        共21页
    摘要 : A method for non-invasive evaluation of diaphragmatic function in humans measuresthe thickness of the diaphragm in real time with an ultrasonic device, and displays the variations of diaphragm thickness versus time. Formulae are g... 展开

    [科技报告]   Cantrell, J. H.   Yost, W. T.        共30页
    摘要 : Non-invasive measuring devices responsive to changes in a patient's intracranialpressure (ICP) can be accurately calibrated for monitoring purposes by providing known changes in ICP by non-invasive methods, such as placing the pat... 展开

    [科技报告]   Sathish, S.   Cantrell, J. H.   Yost, W. T.        共8页
    摘要 : The upper and lower bounds of the bulk, shear, and Young's moduli are calculatedpoint-by-point along the radius of SCS-6 silicon carbide fibers using the Hashin-Shtrikman equations from considerations of the Auger spectra along th... 展开